TS EN 55015 & 61547 standardı Elektromanyetik Uyumluluk (EMC) ürün standartlarındandır Elektrikli aydınlatma ve benzeri donanımın üreticileri, ürünlerini TS EN 55015 & 61547 standardına göre tasarlar

IEC CISPR 15 & 61547 Standards

IEC CISPR 15 & 61547 Standards

EN 55015 & 61547 / IEC CISPR 15 (Edition 9.0) & 61547 (Edition 3.0) Standard

55015; Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

61547; Electromagnetic Compatibility immunity requirements for equipment for general lighting purposes 

CISPR 15 and IEC 61547 are Electromagnetic Compatibility (EMC) product family standards.  Electrical lighting and similar product manufacturers design their products according to CISPR 15 and IEC 61547 standards and have them tested (EMC Test). CISPR 15 & IEC 61547 standards specify the emission and immunity tests requirements for electrical lighting and similar apparatus.


Electromagnetic Compatibility (EMC) Tests:

Electromagnetic Compatibility Tests (EMC Test) are aimed to operate any electrical and electronic device or system without being affected by and affecting other devices or systems in the environment. EMC Tests are examined in 2 general categories as immunity and emission.

Emission Tests specified in CISPR 15;

  • Radiated Emission Test - CISPR 15 / EN 55015
  • Conducted Emission Test - CISPR 15 / EN 55015
  • Harmonics Test - EN 61000-3-2
  • Flicker Test - EN 61000-3-3

Immunity Tests specified in IEC 61547;

  • Electrostatic Discharge (ESD) Test - EN 61000-4-2
  • Radiated Immunity Test - EN 61000-4-3
  • Electrical Fast Transients / Burst Test - EN 61000-4-4
  • Surge Testi - EN 61000-4-5
  • Conducted Immunity Test - EN 61000-4-6
  • Magnetic Fields Test - EN 61000-4-8
  • Voltage Dips and Interruptions Test - EN 61000-4-11

Immunity Test Specifications


Ports

EMC Test

Test Specifications





Enclosure

ESD
EN 61000-4-2

Contact: ±4 kV

Air:±8 kV

Radiated Immunity
EN 61000-4-3

80 MHz – 1 GHz (3 V/m)

%80 AM – 1 kHz

Magnetic Fields
EN 61000-4-8

3 A/m

50-60 Hz







AC 

Voltage Dips and Interruptions Test

EN 61000-4-11

%70 10 cycle

% 0 0,5 cycle

Electrical Fast Transients / Burst Test

EN 61000-4-4

1 kV (5/50 ns, 5 kHz)

Surge Test

EN 61000-4-5

< 25 W

Line toline;0,5kV

Line to ground;1 kV

> 25 W

Line toline;1kV

Line to ground;2 kV

Conducted Immunity

EN 61000-4-6

3 V (150 kHz to 80 MHz)




DC

Electrical Fast Transients / Burst Test

EN 61000-4-4

0,5 kV (5/50 ns, 5 kHz)

Conducted Immunity

EN 61000-4-6

3 V (150 kHz to 80 MHz)




Performance criterion A

During the test, no change of the luminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.

Performance criterion B

During the test, the luminous intensity may change to any value. After the test, the luminous intensity shall be restored to its inital value within 1 min (30 min for high pressure gas discharge lamps). Regulating controls need not function during the test, but after the test, the mode of the control shall be the same as before the test, provided that during the test no mode changing commands were given.

Performance criterion C

During and after the test, any change of the luminous intensity is allowed and the light source(s) may be extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary interruption of the mains supply and/or operating the regulating control.